vitasdk
Documentation of the vitasdk
|
Exports for User. More...
Functions | |
| int | sceSblRtcMgrSetCpActivationKey (void) |
| Set the CP activation key from the activation data managed by the service. | |
| int | sceSblRtcMgrSetCpRtcPhysicalAndKey (int rtc) |
| Set the 32-bit CP physical RTC value and corresponding key. | |
| int | sceSblRtcMgrGetCpSerialId (void *serial_id) |
| Get the CP serial identifier. | |
| int | sceSblRtcMgrSetCpRtcPhysicalForUser (int rtc) |
| Set the 32-bit CP physical RTC value. | |
| int | sceSblRtcMgrGetCpRtcPhysicalForUser (int *rtc) |
| Get the 32-bit CP physical RTC value. | |
| int | sceSblRtcMgrSetCpRtcLogical (int rtc) |
| Request a new 32-bit CP logical RTC value. | |
| int | sceSblRtcMgrGetCpRtcLogical (int *rtc) |
| Get the 32-bit CP logical RTC value. | |
Exports for User.
Include the header file in your project:
Link the library to the executable:
| int sceSblRtcMgrSetCpActivationKey | ( | void | ) |
Set the CP activation key from the activation data managed by the service.
The calling process must be a system program.
| int sceSblRtcMgrSetCpRtcPhysicalAndKey | ( | int | rtc | ) |
Set the 32-bit CP physical RTC value and corresponding key.
The calling process must be a system program, and manufacturing mode is required. FW 3.60 accepts values from 1262314800 through 2145927600 inclusive.
| [in] | rtc | - New physical RTC value. |
| int sceSblRtcMgrGetCpSerialId | ( | void * | serial_id | ) |
Get the CP serial identifier.
The calling process must be a system program, and manufacturing mode is required.
| [out] | serial_id | - Receives exactly 0x80 bytes. |
| int sceSblRtcMgrSetCpRtcPhysicalForUser | ( | int | rtc | ) |
Set the 32-bit CP physical RTC value.
The calling process must be a system program, and manufacturing mode is required. FW 3.60 accepts values from 1262314800 through 2145927600 inclusive.
| [in] | rtc | - New physical RTC value. |
| int sceSblRtcMgrGetCpRtcPhysicalForUser | ( | int * | rtc | ) |
Get the 32-bit CP physical RTC value.
The calling process must be a system program, and manufacturing mode is required.
| [out] | rtc | - Receives the physical RTC value. |
| int sceSblRtcMgrSetCpRtcLogical | ( | int | rtc | ) |
Request a new 32-bit CP logical RTC value.
The calling process must be a system program. FW 3.60 treats rtc as an unsigned 32-bit value and checks that it is from 946652400 through
| [in] | rtc | - Requested logical RTC value. |
| int sceSblRtcMgrGetCpRtcLogical | ( | int * | rtc | ) |
Get the 32-bit CP logical RTC value.
The calling process must be a system program.
| [out] | rtc | - Receives the logical RTC value. |